Safe & Secure Weighing


Reduce Your risk with integrated and intelligent protection systems

Secura® gives you the security and peace of mind of knowing that you have done everything right. Besides providing highly accurate weighing results and operating convenience, Secura® also features built-in protection systems for complete reliability and regulatory compliance – the safe and secure way.

Real-time guidance prompts for leveling, automatic internal adjustment, and 100% traceable, clear documentation with sample and batch identifiers make your lab work more efficient.

Always Correctly Leveled with Sartorius LevelControl

Secura® has an optoelectronic sensor that continuously checks whether the balance is perfectly leveled. If it detects any out-of-tolerances, you will be immediately alerted to this pending risk and see specific guidance prompts to help you level the balance. Output of the weighing data over the interface port will be temporarily interrupted until the balance has been correctly leveled again.

This means you can be certain that only correct data are transmitted. During leveling, you will not have to change from your seated position. More importantly, when working with toxic substances under a laboratory fume hood, you will not have to lean over the balance while leveling it. As a result, Secura® rules out the risk of health hazards.

Stress-Free USP Minimum Sample Weight Measurement

Compliance with the new USP, Chapter 41, requirements (valid from 1st of December, 2013) with absolute process reliability? No problem for the Secura®. SQmin automatically detects and clearly indicates on the display if you are out of the accepted operating range. In addition, the balance will temporarily block the data transfer to a printer or a device connected to its interface port.

This gives you peace of mind knowing that inadequate data cannot be further processed by accident. Our specially trained service staff will determine the operation range for you right at the balance’s site of installation, program it into your Secura® and attach a corresponding verification seal to the balance.

No Risk Due to Temperature Fluctuations

Temperature fluctuations have an influence on the accuracy of your weighing results.

This is why every Secura® comes equipped with the internal adjustment function isoCAL that ensures consistently accurate results. Secura® can be configured to prompt you to launch this procedure or have isoCAL take care of this as soon as an activation threshold is reached.

The Cal Audit Trail function records each isoCAL procedure performed so it can be traced for your quality assurance.

Quality Documentation Made Easy

Secura® features a Cal Audit Trail function to document the quality of each weigh-in procedure you perform.

Each combined calibration and adjustment procedure and each leveling process, including any non-conformities, are recorded by the balance, can be viewed on the touch screen and, if necessary, can be transferred over the balance's interface port to a computer or to a Sartorius laboratory printer.

Security by Password Protection

Secura® comes with password protection to restrict adjustment of the balance settings only to authorized persons. If you set a password, all functions that could change the metrological performance specifications are inactivated.

Cleanability to Secure the Best Results

Cleanliness is one of the main prerequisites in the laboratory to prevent contamination and ensure work area safety. That’s why Sartorius placed a premium on designing Secura® to enable easy and thorough cleaning.

Sleek, resistant surfaces plus clear contours and few edges ensure that Secura® will help you stay compliant with all hygiene requirements. Even the chemically resistant housing makes cleaning the Secura® a breeze.